IDS 1632 Installer Manual 700-256-02K Issued September 2009
16
To default the ID of ALL keypads:
Programming a value of
[3]
into location
[0]
causes ALL keypads to be defaulted.
[INSTALLER CODE] [*] [0] [*] [3] [*]
On pressing the final
[*]
,
wait a few seconds and ALL the keypads will begin flashing. (Do NOT press
[#]
at the end of this sequence, unless you wish the keypad you are using to be registered in the first
address)
Re-enrol all keypads by pressing
[#]
on each keypad – in the CORRECT sequence to ensure that
keypad zone and partition allocation is as required by the user.
5. Event Log
A comprehensive log of the 700 most recent events is retained in the non-volatile EEPROM. The log may
be retrieved using the up/ download software. Alternatively, it can be viewed using an LCD keypad. (See
LCD Keypad Manual)
NOTE:
The exact number of events that can be stored is dependant on the event timing, which means it can vary
between 300 and 1000 events, practically averaging out to be of the order of 500 events.
6. Download Code
The download code (in conjunction with the installer code) is required for download access. The default
download code is 9999. Using the downloading software, it is possible to program a location that will
either allow or disallow defaulting of the download code.
This location is only accessible using the download software. If the panel is defaulted, the
download code will revert back to 9999. A value of [1] [0] programmed into this location will prevent the
download code from being defaulted when defaulting the panel.
6.1 Programming the Panel
The panel can be programmed either via a keypad or via the up/ download software. Programming the
panel by means of an LED keypad is explained below:
NOTE:
Before commencing programming, it is advisable to read the Installer Manual thoroughly.
6.2 Location Values
All values within a program location will be displayed by the zone indicators in binary coded decimal
format i.e. zone indicators 1-4 indicate units (1’s) and zone indicator 5-8 indicate tens (10’s), and so on.
To read a binary value on the keypad sum the values represented by each on LED as shown in Table 1:
Summary of Contents for 1632
Page 1: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 1...
Page 2: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 2...
Page 6: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 6...
Page 7: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 7...
Page 68: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 68...