IDS 1632 Installer Manual 700-256-02K Issued September 2009
25
LOCATION 35
Second Loop Response Time
The first and second loop response times are two preset delay periods that are initiated by the options
selected in locations 1 to 32, sub-location 2, bit 5.
Value Response Time Value Response Time
0
6 ms
8
96 ms
1
12 ms
9
108 ms
2
24 ms (default)
10
120 ms
3
36 ms
11
132 ms
4
48 ms
12
144 ms
5
60 ms
13
156 ms
6
72 ms
14
168 ms
7
48 ms
15
180 ms
LOCATION 36
Cross-Zone Delay Timer
This location defines the cross-zone delay timer period.
Value
Response Time
0
3 seconds
1
10 seconds
2
15 seconds
3
20 seconds (default)
4
25 seconds
5
30 seconds
6
45 seconds
7
1 Minute
LOCATION 37
Cross-Zone Count (Default = 2)
If the panel is armed and the total number of violations of zones programmed as cross-zones reaches
this count within the time period programmed into location 36, an alarm condition will be registered.
Program a value from [0] to [1] [5]. A [0] will disable this location. Program zones as cross-zones in sub-
location 2 of locations 1 to 16. Any single zone enabled for cross zoning, which is violated continuously
for the time specified in Location 36 will also register an alarm condition.
Summary of Contents for 1632
Page 1: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 1...
Page 2: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 2...
Page 6: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 6...
Page 7: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 7...
Page 68: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 68...