IDS 1632 Installer Manual 700-256-02K Issued September 2009
8
1. Introduction to the IDS 1632
The IDS 1632 is a versatile, microprocessor based sixteen zone Alarm Panel. It has eight partitions and
can be expanded to thirty two zones. Most features are optional and may be programmed either directly
through the keypads or via the telephone system, using the IDS download software and appropriate
modem.
There are sixteen programmable burglary zones, a dedicated panic zone, monitored siren output,
auxiliary power outputs and eight programmable outputs that may be programmed to perform various
trigger/switching functions.
The IDS 1632 also interfaces to a Voice Module, GPRS module and may be controlled remotely via DTMF
telephone keypad.
The voice module makes it possible to have the Alarm Panel call a user’s telephone number and report in
plain English. The user may also access the Panel, using DTMF keystrokes and be guided through a
menu system by English Voice Prompts.
IDS GSM Communicators (GPRS modules) are available in two versions:
The SMS Communicator allows clients to control and program their Alarm Panels via a cellphone
– it also allows up to 5 cellphones to receive SMS event reporting.
Outstation Communicators connect the clients’ Alarm Panels to the Security Company Control
Room via a third party Communications Watchdog Company (which monitors signal strength
levels and ensures that reports are acknowledged.) Alarm Companies are also able to
program/upload/download the clients’ IDS 1632 Alarm Panels by means of an IDS GSM Base
Station Communicator and the associated Download Software.
For correct operation, the IDS 1632 must be used in conjunction with the specified transformer/battery
combination and appropriate peripheral sensors and signalling devices.
1.1 Features of the IDS 1632
RS485 keypad bus supports two eight-zone expander modules, one IDS remote receiver, up to
16 keypads and an IDS GSM Communicator.
Sixteen programmable, end-of-line supervised zone inputs
.
Expandable to thirty two zones via
keypad zones, zone expander modules, zone doubling or
wireless expansion.
8 partitions
Optional tamper reporting per zone using double end-of-line resistors (12K and 4K7)
Fully programmable digital telephone communicator that supports most industry standard
formats.
Eight programmable outputs on Alarm Panel. Expandable to twelve when using Wired Zone
Expander module.
Non-volatile EEPROM memory retains all program and event log data in the event of a total
power failure.
Event log, date and time stamped (approximately 700 events – exact number of events is
dependant on the timing of the events).
Programmable loop response time
Up and downloadable using IDS Windows based software, either directly via RS 232 or remotely
using a modem.
Summary of Contents for 1632
Page 1: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 1...
Page 2: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 2...
Page 6: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 6...
Page 7: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 7...
Page 68: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 68...