FDX-32 Command Guide
73
@GFS
Cooling fan status
Function
Getting
Format
@GFS
Return value
@GFS,rpm1,s1, rpm2,s2, rpm3,s3, rpm4,s4, rpm5,s5, rpm6,s6, rpm7,s7 (, rpm8,s
8, rpm9,s9, rpm10,s10)
Parameter
rpm1 to rpm10: The number of cooling fan rotation speed
rpm8 to rpm10: only if redundant power supply unit is mounted.
s1 to s10 : Status
s8 to s10: only if redundant power supply unit is mounted.
0 = Normal, 1 = Abnormal
Example
@GFS
@GFS,3540,0,3540,0,3540,0,3540,0,354
0,0,3540,0,3540,0
Getting the number of cooling fan
rotations.
All cooling fan speed: 3540; status:
Normal
Remarks
-
@GPS
Voltage status
Function
Getting
Format
@GPS
Return value
@GPS, status1 (,status2)
Parameter
Status1 to status2: status
Status2: only if redundant power supply unit is mounted.
0 = Normal, 1 = Abnormal
Example
@GPS
@GPS,0
Getting voltage status.
Status1: Normal
Remarks
-
@GDS / @SDS
Front power key
Function
Getting
Setting
Format
@GDS
@SDS,onoff
Return value
@GDS,onoff
@SDS,onoff
Parameter
onoff
:
Front power key
0 = Front power key “OFF”, 1 = Front power key “ON” [Default]
Example
@GDS
@GDS,1
Getting front power key status.
Getting front power key: ON
@SDS,1
@SDS,1
Setting front power key to ON.
Completed normally.
Function
The start process (OFF to ON) takes eight seconds for initialization. During the process,
communication command controls are disabled.
When the front power key is set to OFF, only the following commands are enabled.
@GIV, @GPS, @GFS, @GDS / @SDS