FDX-32 Command Guide
44
@GTP / @STP
Test pattern output
Function
Getting
Setting
Format
@GTP,out_ch
@STP,out_ch,pattern
Return value
@GTP,out_ch,pattern
@STP,out_ch,pattern
Parameter
out_ch: Output channel
1 to 32 = OUTPUT1 to OUTPUT32
- 2 = Scan converter output slot board is not installed..
pattern : Test pattern
0 = OFF: No test pattern [Default]
1 = V-STRIPES (Black/white stripes)
2 = CROSS HATCH (Plaid)
3 = WHITE RASTER (All white)
4 = RED RASTER (All red)
5 = GREEN RASTER (All green)
6 = BLUE RASTER (All blue)
7 = COLOR BAR (colored bar)
8 = 16STEP GRAY (16-step grayscale)
9 = 256STEP GRAY (256-step grayscale)
Example
@GTP,1
@GTP,1,0
Getting the current test pattern of output
channel1.
“0” (OFF: No test pattern) is set.
@STP,1,0
@STP,1,0
Setting test pattern of output channel1 to
“0” (OFF: No test pattern).
Completed normally..
Remarks
Supported since firmware ver.2.xx.