Part 2 - Configuration
67
Camera System_Recording Fail
●
Activation Time
: Specify how long recording fail
has to last in order for it to be considered as an
event. When the recording fail is not detected for the
specified duration of time, it will not be considered as
an event.
●
Actions
: Specify which actions to take when a
Recording Fail event occurs.
–
Record
: Specify which cameras to begin linked
recording on when an event occurs. If the schedule
is set to
Event
or
Time & Event
mode, the selected
cameras will begin linked recording when an event
occurs.
–
Alarm-Out
: Designate event-triggered alarm-out
channels (each for the NVR and camera) and beeps.
–
Notify
: Configure to be notified of events by Mail,
LAN1 through 5, Push, HTTP, FTP, and/or Alert
Window.
–
PTZ
: Moves the PTZ camera to a specific preset
position when an event occurs.
–
Event Monitoring:
Selects the cameras to monitor
when an event occurs.
In order to use the Callback feature, the NVR must
be registered on the remote program.
Camera System_PIR
This event occurs when the PIR sensor mounted on the
camera is used to sense motion. Since the PIR sensor
detects the temperature of the human, it can detect
motion even in dark places without light.
●
No.:
Select which cameras to apply PIR to.
●
Sensitivity
: Set sensitivity settings between 1 (Low)
and 5 (High).
●
Reference Event
: Set condition for event to occur
using the PIR sensor. A PIR event occurs when a
motion occurs after an event set as a reference event
has occurred. You can set Motion and Trip Zone as
reference events.
•
In order to use the Callback feature, the NVR must
be registered on the remote program.
●
Ignore Condition
–
Ignoring Interval:
The system does not produce
event log entries or remote notifications for events
detected within a certain period of time after PIR
events of the camera channels are detected. Set the
value between 1 sec and 5 secs or choose Never.