60
E.
Touch Enter New Password text box. (Sets focus so the new password can be en-
tered.)
F.
Using the number pad, touch the desired digits of new password.
G.
Touch ENTER button.
H.
Wait for PASSWORD SAVED to appear. See Figure 59.
Figure 59. Security Tab - Password Saved
I.
Touch Home button.
6.2.1.4
How To Assign/Change Low Tank Water Alarm Trigger Level
Perform the following to change/set the trigger level for the low tank water alarm trigger point.
A.
On Pump Controller, touch and hold system options button until loading icon
completes circle and Menu screen (Figure 50, page 38) is displayed.
B.
Touch Password Entry button.
C.
On Pump Controller, System Options, Password Entry screen (Figure 61,
page 61), sequentially touch password digits.
NOTE
See Table 7, page 51, for the applicable password to set the Warning active at 5/8,
4/8, or 3/8 full point.
D.
Touch ENTER button.
E.
Touch Exit button.
F.
Touch Back To Previous Screen button. (See Table 3, page 14.)
6.2.2
How To Configure Pump Controller Parameters
To configure the SAM Speaks volume level, name (or rename) a camera (display for video tab),
calibrate the ITL-40 (water level for the onboard water tank), or change the way the onboard wa-
ter tank level is displayed on the TANK tab of the Pump Controller enter the appropriate access
password listed in Table 7 (page 51).
A.
On SAM Pump Controller, touch System Options icon (touch and hold icon if re-
quired). See Figure 60.
Summary of Contents for Hale Sam