Table 5. SAM To OEM Connection Point Cross Reference Listing - CONTINUED
Label (NOTE 1/)
SAM Component/Item
OEM Component/Item
TO ATMOSPHERE
Plumbing Fitting(s)
Consists of a fitting on the
SAM Drain Manifold Assy
No connection required.
CONNECT TO MASTER DRAIN Multiple Plumbing Fittings
Connect to master drain
NOTE 6/
Discharge valve drain port
(Next to the pressure sensor.)
Connect to individual isolated drain
(Do NOT group or connect to master
drain assy.)
CALIBRATED PRESSURE
SENSOR, ADJUST AT FITTING
Discharge Valve Pressure Sen-
sor Fitting (between senor and
valve body)
Rotate fitting if sensor orientation
change is required (Additional changes
may require preforming a calibration.)
NOTE 1/ When multiple connections are required multiple labels/tags will be provided.
NOTE 2/ N/A for a Hale built module. (Hale makes the connection at the factory.)
NOTE 3/ N/A if option is not purchased.
NOTE 4/ The attached pressure sensor must be mounted to provide the detected level for
that tanks content.
Note 5/
At the onboard water tank access/fill tower, route the 3/4-in flex line to
prevent (to maximum extent possible) incidental items (bags of oil dry,
spare supply containers, etc.) from being placed on the tubing and dam-
aging/breaking it.
Note 6/ Each discharge valve drain requires an individual isolated drain.
5.7
SAM Software And Configuration Passwords
SAM utilizes two levels of password entry; OEM/Technical and user/dealer. The OEM/Technical
level requires the use of a USB key in addition to entering the password. The user/dealer level
ONLY requires a password entry. See Table 6 for a list of the SAM Control Center passwords and
Table 7 for the SAM Pump Controller passwords.
Table 6. SAM Control Center Password List
Password
Level
Description Of Access
12345
User/Dealer
Discharge Quickset Menu
23456
User/Dealer
Color(s) assigned to valve(s) (discharge and Intake),
Friendly Name (Discharge and Intake), Preset, Quicksets,
and user/dealer password
23364
User/Dealer
Configuration Mode
Only Available To
Verified OEM/
Apparatus Build-
ers/Select Tech-
nicians
OEM/Technician
(Requires USB key)
Individual Valve Stop, Master pressure sensor zero, Mas-
ter pressure sensor span, user password reset, revert to
IDEX Permanent Valve Configuration, Error Code List
(Not
clearable), CAN Data Logger (Downloadable to USB), Low
intake pressure control trigger value, Language