123
8.
ADJUSTMENTS
This section provides descriptions of the SAM system adjustments and calibrations. This section also
provides step by step instructions for the performance of SAM system adjustments and calibrations
that may be performed by operators, installers, or maintenance personnel.
8.1
ITL–40 Calibration Using SAM Pump Controller
PERFORMING THIS PROCEDURE CAUSES SAM TO EXIT AUTO MODE.
Perform the following to calibrate the WATER LEVEL ITL-40 display (see Figure 127) using the Pump
Controller.
Figure 127. ITL-40 Display
A.
Fill onboard water tank completely.
B.
On Pump Controller, touch and hold system options button until loading icon com-
pletes circle and Menu screen (Figure 50, page 38) is displayed.
C.
Enter ITL-40 Calibration password (see Table 7, page 51). ITL CALIBRATION screen
appears (see Figure 128).
Figure 128. ITL-40 Calibration Screen