85
6.3.2.2
Opening A Discharge
A PRESSURE HAZARD MAY EXIST EVEN WHEN THE PUMP IS NOT RUNNING. PRIOR TO
REMOVING HOSES OR CAPS FROM PUMP CONNECTIONS, RELIEVE PRESSURE BY
OPENING DRAINS. BLEEDER VALVES SHOULD ALSO BE USED WHEN CONNECTING TO
AN INTAKE FROM A PRESSURIZED SOURCE.
Perform the following, as applicable and/or as desired, to manually (electronically) open a dis-
charge (typically Step A. or Step B.). To physically override a discharge valves position, see para-
On operator panel, using SAM Control Center, open desired discharge as follows.
Display MANUAL VALVE CONTROL screen as follows.
a)
On SAM Control Center (from the SAM landing screen or from the Auto Mode Home
screen) touch MANUAL MODE button. (See Figure 56, page 56.)
b)
Touch YES button on acknowledgment popup. (See Figure 57.)
Touch and hold + button on valve close/open icon group for desired dis-
charge. (All progress bars eventually illuminate and the + button transitions
to the VALVE OPEN indicator. The VALVE CLOSED indicator transitions to the—
button as soon as the valve partially opens.) (Similar to Figure 98.)
B.
Optionally, ONLY on associated Navigator Pro, open desired Akron Brass valve as
follows.
PERFORMING THIS PROCEDURE CAUSES SAM TO EXIT AUTO MODE.
THE NAVIGATOR PRO ASSOCIATED WITH A DISCHARGE VALVE DOES NOT OPERATE THE
VALVE (PRESSURE READING FUNCTIONS AS A DISPLAY ONLY) WHEN SAM IS IN AUTO
MODE.
NOTE
The Navigator Pro may be a model 9323 or a model 9335 and are provided ONLY as
an option.
If using a Navigator Pro 9323, reference paragraph 8.1, Opening and closing
the valve, in Style 9323 Navigator Pro Valve Controller Installation, Operating,
And Maintenance Instructions (P/N 123251).
If using a Navigator Pro 9335, reference paragraph 8.1, Opening and closing
the valve, in Style 9335 Navigator Pro With Pressure, Flow CAFS And Valve
Control Installation, Operating, And Maintenance Instructions (P/N 126914).
6.3.2.3
Closing A Discharge
A PRESSURE HAZARD MAY EXIST EVEN WHEN THE PUMP IS NOT RUNNING. PRIOR TO
REMOVING HOSES OR CAPS FROM PUMP CONNECTIONS, RELIEVE PRESSURE BY
OPENING DRAINS. BLEEDER VALVES SHOULD ALSO BE USED WHEN CONNECTING TO
AN INTAKE FROM A PRESSURIZED SOURCE.
Summary of Contents for Hale Sam
Page 2: ......
Page 24: ...10 THIS PAGE INTENTIONALLY BLANK...
Page 27: ...13 14 BLANK Figure 2 SAM Network Diagram CAN Buses...
Page 28: ......
Page 68: ...52 THIS PAGE INTENTIONALLY BLANK...
Page 138: ...122 THIS PAGE INTENTIONALLY BLANK...