SE2L User’s Manual (SE9Z-B1865)
111
7.15.2 Area configuration by teaching function
Automatic zone configuration by referring the boundary can be done by using the SE2L’s Teaching
function. This function is useful when user needs to configure complex zone or would like to reduce the time
for zone configuration. Steps below show the configuration procedures using the teaching function.
Ensure the SE2L is connected with the PC.
Click on the Teaching
button.
Enter the offset to be applied between the zone and the background (Max offset 2100mm).
Click the “Teach” button (Figure 7-43).
Figure 7-43 Teaching setting
Figure 7-44 Area configured by teaching
After the area is created automatically it can be edited using the drawing tools.
Obtaining the background data starts when the “Teach” button is clicked. Configured area will resemble
the SE2L’s background. (Figure 7-44). When configuring the protection zone, if the background is not
within the maximum detection distance it is set to maximum detection distance of SE2L. In case of
warning area, if there is no background within 20m from SE2L it will be set to 20m.
Summary of Contents for SE2L-H05LPC
Page 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual...
Page 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area...
Page 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm...
Page 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm...
Page 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm...
Page 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm...
Page 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm...
Page 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm...
Page 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm...