51
istor system store -
Installation and Servicing
SERVICING
ist9845
69 IGNITION ELECTRODE REPLACEMENT
70 FLAME SENSING ELECTRODE REPLACEMENT
1.
Refer to Frame 53 & 54.
2.
Remove the boiler sealing panel. Refer to Frame 56.
3.
Unplug the spark electrode lead from the spark generator.
4.
Undo the 2 retaining screws holding the spark electrode to
the combustion chamber.
5.
Remove the earth lead from the ignition electrode.
6.
Remove the electrode, taking care not to dislodge the
grommet from the casing.
7.
Fit the new ignition electrode, using the new gasket
supplied, check dimensions as shown.
8.
Re-assemble in reverse order and check that no damage to
the combustion chamber insulation has occurred during
electrode replacement.
9.
Check the operation of the boiler. Refer to Frame 49.
68 CONTROL THERMISTOR, RETURN THERMISTOR
AND OVERHEAT THERMOSTAT REPLACEMENT
1.
Refer to Frame 53 & 54.
2.
Unclip the thermistor / thermostat from the flow / return
pipe and withdraw it from the controls compartment.
3.
Disconnect the electrical leads from the thermistor /
thermostat.
4.
Re-connect the electrical leads and re-assemble in
reverse order ensuring that the spring clip is securely
on the pipe.
5.
Check the operation of the boiler. Refer to Frame 49.
Note.
O/H thermostat on flow pipe - orange wires
Flow thermistor on flow pipe - red wires
Return thermistor on return pipe - pink wires
ist9852
4
5
1.
Refer to Frame 53 & 54.
2.
Remove the boiler sealing panel.
Refer to Frame 56.
3.
Unplug the sensing electrode lead
from the control box.
4.
Undo the 2 retaining screws
holding the sensing electrode
to the combustion chamber.
5.
Unbolt the sensing electrode
earth lead from the earth point
beneath the boiler.
6.
Remove the electrode,
complete with grommet.
7.
Fit the new sensing electrode, using the
new gasket supplied, check dimensions
as shown.
8.
Re-assemble in reverse order and check that no
damage to the combustion chamber insulation has
occurred during electrode replacement.
9.
Check the operation of the boiler. Refer to Frame 49.
ispfu9801
SER
VICING
Summary of Contents for istor HE260
Page 2: ...2 istor system store Installation and Servicing...
Page 73: ...73 istor system store Installation and Servicing...
Page 74: ......
Page 76: ...Gas Safe Register ID Number...
Page 78: ...78 istor system store Installation and Servicing...
Page 79: ...79 istor system store Installation and Servicing...