19
istor system store -
Installation and Servicing
INSTALLATION
13 FITTING THE PRE-PIPING FRAME
1.
Using the cardboard template mark the position of the
appliance and the fixing holes for the pre-piping frame.
2.
Fasten the pre-piping frame to the floor.
Using suitable fixing screws and plugs dependant on the
floor material, fasten the pre-piping frame to the floor.
Take care not to pierce any underfloor piping or electrical
wiring.
Note.
Pipe runs to the service connections on the piping frame
must be from the front, back or below, and not cross the
side channels of the frame, where the appliance will slide
on and stand.
14 WATER (DHW) CONNECTIONS
Domestic Hot Water Connections
Refer to the Note in Frame 13, for guidance.
IMPORTANT
Do not subject any of the isolating valves to heat as the
seals may be damaged
.
ist8339
ist8991
The PRV (pressure reducing valve) provided in the
hardware pack MUST be fitted in a convenient point on
the mains cold inlet to the appliance. Once fitted, a
pressure balanced cold feed to mixer taps and
showers may be taken downstream of the PRV but
before the istor appliance.
Note.
1.
The PRV has a built in serviceable water filter. It
must therefore be located in a suitable place for
future maintenance.
2.
It is pre-set to deliver water to the istor at 2 bar to
ensure safe operation of the DHW system.
ist8337
Hot
Out
Cold
In
Pressure balanced
cold feed to mixer
taps and showers
Mains
cold in
To taps and
showers
Pressure
reducing
valve
3.
The pressure reducer can be installed with the
pipework either vertical or horizontal. However it
must not be installed upside down.
4.
To obtain optimum DHW delivery from the
appliance all DHW pipes should be run in 22mm.
Note
.
When installing the PRV,
consideration should be given to
the use of isolation valves either
side of the PRV for future
servicing and maintenance.
INST
ALLA
TION
Summary of Contents for istor HE260
Page 2: ...2 istor system store Installation and Servicing...
Page 73: ...73 istor system store Installation and Servicing...
Page 74: ......
Page 76: ...Gas Safe Register ID Number...
Page 78: ...78 istor system store Installation and Servicing...
Page 79: ...79 istor system store Installation and Servicing...