4
istor system store -
Installation and Servicing
GENERAL
Boiler size
istor HE260
istor HE325
Gas supply
2H - G20 - 20mbar
Gas Supply Connection
Rc 1/2 (1/2” BSP female)
Injector size
Stereomatic 5.6mm dia.
Inlet Connection
Domestic Hot Water
22mm copper
Outlet Connection
Domestic Hot Water
22mm copper
Flow Connection
Central Heating
22mm copper
Return Connection
Central Heating
22mm copper
Flue Terminal Diameter
mm (in)
100 (4)
Average flue temp/mass flow rate
(DHW)
74
o
C / 20.3g/s
Maximum Working Pressure (Sealed Systems)
bar (lb/in
2
)
2.5 (36.3)
Maximum Domestic Hot Water Inlet Pressure
bar (lb/in
2
)
10.0 (145)
Minimum Domestic Hot Water Inlet Pressure
bar (lb/in
2
)
0.5 (7)
Maximum Domestic Hot Water Outlet Pressure
bar (lb/in
2
)
2.0 (29)
Temperature & Pressure relief valve
Preset 95
o
C / 4.0 Bar opening
Electrical Supply / Power consumption
230 V ~ 50 Hz. / 148 W
Fuse Rating
External : 3A
Internal : 3.15A TL250 V
Water content
Central Heating litre (gal)
2.0 (.44)
Domestic Hot Water
80 litre
120 litre
Packaged Weight - Boiler box
kg (lb)
58.5 (129)
58.5 (129)
Packaged Weight - Tank box
kg (lb)
66 (145)
73 (161)
Maximum Installation Weight -Boiler box
kg (lb)
55 (121)
55 (121)
Maximum Installation Weight -Tank box
kg (lb)
59 (130)
65 (143)
Boiler Casing Size
Height mm (in)
1400 (55)
1600 (63)
Width mm (in)
560 (22)
560 (22)
Depth mm (in)
600 (23.6)
600 (23.6)
Potable water components on tank module
Pressure reducing valve
preset to 2 bar
Thermostatic mixer
max inlet temp 85
o
C/max pressure 14 bar
Pressure and temp relief valve on cylinder
90
o
C and 4 bar
Pressure relief valve on inlet manifold
3 bar
DHW expansion vessel
19 litres, precharged to 2 bar
Table 1 - General Data
Note.
Gas consumption is calculated using a
calorific value of 38.7 MJ/m
3
(1038 Btu/ft
3
)
gross or 34.9 MJ/m
3
(935 Btu/ft
3
) nett
To obtain the gas consumption at a different
calorific value:
a. For l/s
- divide the gross heat input (kW) by
the gross C.V. of the gas (MJ/m
3
)
b. For ft
3
/h
- divide the gross heat input (Btu/
h) by the gross C.V. of the gas (Btu/ft
3
)
Key to symbols
IE
=
Ireland,
GB
= United Kingdom (Countries of destination)
PMS
= Maximum operating pressure of water
C
13
C
33
C
53
= A room sealed appliance designed for connection via ducts to a
horizontal or vertical terminal, which admits fresh air to the burner
and discharges the products of combustion to the outside through
orifices which, in this case, are concentric. The fan is up stream
of the combustion chamber.
I
2H
= An appliance designed for use on 2nd Family gas, Group H only.
* The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by a notified body.
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning
of this appliance, care should be taken when handling edges of sheet steel components.
Table 2 - Performance Data - Central Heating
Maximum
DHW Input :
Nett CV
kW
30.2
(Btu/h)
(103 100)
Gross CV
kW
33.5
(Btu/h)
(114 300)
Gas Consumption
l/s
0.87
(ft
3
/h)
(110)
Maximum
DHW Output
kW
29.3
(Btu/h)
(100 000)
DHW Storage Temp
70
o
C
DHW Delivery Temp
Factory set
60
o
C
Variable on Installation only
45
o
C-65
o
C
DHW Flow Rate
HE260 HE325
(Practical maximum assuming
suitable mains supply)
l/min
35
35
DHW Recovery from 15
0
C
min.
14
20
After 70% draw off
min.
9
12
Table 3 - Performance Data - Domestic Hot Water
Boiler Input :
Max.
Min.
Nett CV
kW
24.4
9.1
(Btu/h)
(83 300)
(31 000)
Gross CV
kW
27.1
10.1
(Btu/h)
(92 500)
(34 400)
Gas Consumption
l/s
0.70
0.26
(ft
3
/h)
(89.1)
(33.2)
Boiler Output :
Non Condensing
kW
23.4
8.8
(Btu/h)
(80 000)
(30 000)
Condensing
kW
25.1
9.6
(Btu/h)
(83 700)
(32 800)
Seasonal efficiency (SEDBUK)*
Band A [90.1]%
NOx Classification
Class 5
Summary of Contents for istor HE260
Page 2: ...2 istor system store Installation and Servicing...
Page 73: ...73 istor system store Installation and Servicing...
Page 74: ......
Page 76: ...Gas Safe Register ID Number...
Page 78: ...78 istor system store Installation and Servicing...
Page 79: ...79 istor system store Installation and Servicing...