18
Concord ESi
- Installation and Servicing
INSTALLATION
21 ASSEMBLING THE DRAUGHT DIVERTER
CON5268
A
!
"
CON5269
22 DRAUGHT DIVERTER
-
Stick the self-adhesive cord (1) on the top of
the body.
Start on the centre of the back side.
-
Apply a silicone bead (2) as shown on the
picture (only on the front side of the boiler).
-
Remove the nuts pre-mounted on the
draught diverter and fit the draught diverter
stiffener (3).
The nuts will be finally tightened after Frame
33, after mounting and adjusting the side
panels.
-
Put the draught diverter (4) in place and
fasten it onto the body using 4 H8 x 30
4 DE8 serrated w 4 nuts
+ 4 M8N washers.
INST
ALLA
TION