![IDEAL 33-772 Manual Download Page 5](http://html1.mh-extra.com/html/ideal/33-772/33-772_manual_3607401005.webp)
Results of a 2-pair cable, where 3-6 pair found open
1. When a pair or wire was found, the two
missing pin numbers in line 2 of the
wire map indicates the open pair;
2. The last line shows an error message
“3-6”
Results of a 2-pair cable, where 1, 2 wire of M12 or 1, 3 wire of
RJ-45 found shorted
1. When a single wire was found shorted
with another one, the two missing pin
numbers in line 2 of the wire map
indicates the shorted pair;
2. The last line shows an error message
“Short 13”
Test results of a 2-pair cable, where 3,4 wire of M12 or 2,6 wire of
RJ-45 found shorted:
1. When a single wire was found shorted
with another wire, the two missing pin
numbers in line 2 of the wire map
indicates the shorted pair;
2. The last line shows an error message
“Short 26”
Test results of a 2-pair cable, where 1,2 wire of M12 or 1,3 wire of
RJ-45 found mis-wired:
1. When there is miswire the wire map
shows the pin numbers;
2. An error message
“Miswire 13”
appears on the last line.
RJ-45 - for 4-pair data cable test
When RJ-45 mode is selected and no
cable is connected, the display shows:
Fail
M12>RJ45
1234 Shielded
1 2
ID 1
Open 3-6
Fail
M12>RJ45
1234 Shielded
**26
ID 1
Short 13
Fail
M12>RJ45
1234 Shielded
13**
ID 1
Short 26
Fail
M12>RJ45
1234 Shielded
3126
ID 1
Miswire 13
Test
RJ45
12345678
Open 1-2 3-6 4-5 7-8
1-2, 3-6, 4-5, 7-8 No Cable
5