3
Results of a cross-over, shielded cable
1. “Pass” shown on the first line;
2. Wire Map shows wiring configuration
1324
and ID # indicates the particular
Remote which is in use;
3.
“M12 X-Over” displayed on the
last line;
4. Beeper icon appears only when Beeper is OFF; low battery icon appears
only when the battery is below 5.5V
M12 to RJ-45
Cable Test
When in M12 > RJ-45 mode and no cable
is connected, the display shows:
1 M12>RJ45 mode
2. “No shield” is default setting
3. Exit to SETUP for more options
(see Set Up mode)
4. When using M12>RJ45 mode, the
Split Pair function is automatically
disabled.
Setup
To change between shielded and unshielded cable, toggle Beeper to select
length units.
When in SETUP mode -
• Use Up or Down arrow keys and scroll
to Shielded and Unshielded, press
SELECT to change.
• Selectable Pass Beep-On and Pass
Beep-Off function is also available in this SETUP mode, press Up or Down
keys to select and press SELECT to choose. (Note: Beeper sounds when test
passes, and when voltage is detected.)
• In this mode, press Up and Down keys to select between units of length,
Units-feet or Units-meters, press SELECT key to select.
Standby - Cable Test (Pre-Test)
1. When in M12 > RJ-45 mode,
2. Connect cable to the Tester (see
following screens for more
demonstrations)
Note: When there is no remote connected,
shield and no shield will not appear
PASS
M12
1234 Shielded
1324
ID 1
M12 X-Over
Test
M12>RJ45
1234
Open
1-2 3-6
Displays and cycling in sequential order
1-2, 3-6, No cable
Cycling in sequential order 1 2, 3 4
SETUP
Unshielded
SEL to change
Test
M12>RJ45
12 34
Pass Pre-Test
15.5 ft