12
Screen #L-6
When length measure mode works on a
4-pair data cable and if a short at 1-2 pair is
detected; the screen displays as:
1. Whenever there is a short, the fault
message replaces length reading;
Screen #L-7
Change length constant, the screen displays:
1. To change length constant, press Up and
Down keys to adjust pF value,
2. CAL icon is on while adjusting the length
constant, goes off when it is done,
3. Exit to SETUP mode to select unit of length
between ft and meter.
Screen #L-10
To select COAX (RJ-45) as type of cable to measure
1. Use Up and Down arrow keys to select
Coax(RJ45) cable to measure its length;
2.
When measuring length of a coaxial
cable, no remote is required;
3.
1-2 is default pair and must be used
for coax length measure.
Screen #L-11
When measuring a good Video (coax) cable length; the screen displays as:
Remarks:
1. If there is a short, the error message
replaces the length reading;
2. To change length constant, press Up and
Down keys
3. CAL icon is on while adjusting the length
constant, goes off when it is done
Screen #L-12
When auto is selected, all the pair wires will
be tested and measured, if the cable is
normal, the screen displays as:
• Measuring a cable which is connected to a
network device, length reading is shown on
third line and a question “T-Ring Network?”
or “XBase-T Network?” apears on the last line of the display.
RJ45
LENGTH
Shorted 1-2
15.000pF/ft
RJ45
LENGTH
CAL
0 ft 1-2
16.000pF/ft
M12
M12>RJ45
RJ45 COAX(RJ45)
Select type to measure
length
MODE=ESC, SEL=go
COAX(RJ45)
LENGTH
6.0 ft auto
16.250pF/ft
1-2 is default pair for measuring coax cable
length, displays as “auto” on the screen.
RJ45
LENGTH
6.0 ft auto
Xbase-T Network
PK Elektronik Vertriebs GmbH, E-Mail: [email protected], Internet: www.pkelektronik.com