20
Installation and Servicing
SECTION 2 - INSTALLATION
2.10 FITTING THE WALL MOUNTING BRACKET - EXTERNAL BOILER
1.
Align the template on the wall, ensuring
adequate clearances are met, as
defined in Section 1 and level and mark
the 6 holes.
2.
Drill the 6 holes with the appropriate
masonry drill size required for the
masonry plugs used.
3.
Insert all 6 masonry plugs ensuring a
flush fit to the wall, and insert the top
two mounting screws, leaving screws
approximately 10mm proud.
4.
Carefully lift the mounting bracket into
position and onto the upper two screws
aligning with the two slotted holes.
5.
Attach the 4 remaining screws, and
secure the bracket to the wall. Ensure
that all screws are secured flush, and
the mounting bracket is flat and level
with no twisting or bending.