18
Installation and Servicing
SECTION 2 - INSTALLATION
V - See Diagram in
Section 1.16
Extended centre line
155
The wall mounting template is located on the internal protective
packaging. The template shows the position of the fixing and rear
flue centre holes for a standard installation
Care MUST be taken to ensure the correct holes are drilled.
1.
Tape template into the required position, ensuring its squareness
by hanging a plumbline as shown.
2.
If fitting a side flue, extend the flue centreline onto the side by
155mm
on a standard wall fix.
3.
Mark the following on to the wall:
a
The selected group of wall mounting screw holes.
b.
The centre position of the flue duct. Marking both the centre
and the circumference of the flue duct.
4.
Remove the template plate from the wall.
2.6 WALL MOUNTING TEMPLATE
2.5 FRONT PANEL REMOVAL
1.
Loosen the 2 screws retaining the front panel.
2.
Pull the two clips downwards to disengage.
3.
Pull the front panel forward and upwards to remove.