46
SECTION 3 - SERVICING
Installation and Servicing
46
1,4
2
3.2 BOILER FRONT PANEL REMOVAL / REPLACEMENT
3.3 LOWERING THE CONTROLS PANEL / ACCESSING MAINS WIRING
3b
1
1
. Once the front panel has been removed
the controls panel can be hinged down
to access the wiring and electronics or
the internal components of the boiler.
2. To lower the panel further (position 2)
squeeze the 2 clips inward and hinge
the panel into a lower position.
3. To gain access to the mains wiring
connections, remove retaining screw,
press the retaining lug to the left and lift
off the cover.
Position 1
2
Position 2
Clip
REMOVAL
1.
Loosen the 2 screws retaining the front panel at
the underside of the boiler.
2.
Release catches at underside of the front panel by
pulling downwards.
3a.
Pull the underside of the front panel forward then
lift upwards to remove.
REPLACEMENT
3b.
Engage the top of the front panel on the locating
lugs and push the panel back into position until the
catches click into place.
4.
Re-tighten the securing screws.
3
SER
VICING
Summary of Contents for VOGUE MAX SYSTEM 15