Ideal offers the following kit:-
(see kit for installation instructions)
Weather Compensation Kit
: Allows outside temperature sensing.
Ideal Touch Heat & System RF Programmable Room Thermostat:
Transceivers fit into boiler. Portable room thermostat.
2.18 OPTIONAL SYSTEM CONTROLS KITS
The Vogue Max System boiler comes pre-fitted with a red link wire between the SL1 connections and a violet link wire between
the OpenTherm connections of the installer wiring connections. This creates a permanent call for heat and the appropriate link
must be removed when adding a Room Thermostat/Timer. For 230V remove the SL1 link, for PELV remove the OpenTherm link
2.19 INTERNAL WIRING - EXTERNAL CONTROLS
To add wired external Room Thermostats, Timers or
Programmers proceed as follows:-
1. Isolate the mains supply to the boiler.
2. Remove the front panel (refer to Section 3.2).
3. Swing the control box down into the servicing position
(refer to Section 3.3).
4. Route incoming cables through the grommets in the
bottom panel (note: grommets are ‘blind’ and will require
puncturing) and secure using clamps and screws provided
in the hardware pack.
5. Remove the installer wiring cover.
6. Connect wires to the appropriate plug, which may be
removed to aid wiring.
7. Re-assemble in reverse order.
WARNING: UNDER NO CIRCUMSTANCES MUST A 230V CONNECTION
BE MADE TO THE OPENTHERM OR WEATHER COMPENSATION CONNECTIONS
INST
ALLA
TION
Summary of Contents for VOGUE MAX SYSTEM 15
Page 4: ...4 Installation and Servicing...
Page 6: ...6 Installation and Servicing...
Page 68: ...68 SHORT LIST OF PARTS Installation and Servicing...
Page 74: ...74 Installation and Servicing NOTES...
Page 75: ...75 Installation and Servicing NOTES...
Page 76: ...76 Installation and Servicing NOTES...
Page 77: ...77 Installation and Servicing NOTES...
Page 78: ...78 Installation and Servicing NOTES...