50
SERVICING
ESPRIT 2 -
Installation and Servicing
69
CONDENSATE 'S' TRAP REPLACEMENT
1.
Refer to Frame 57.
Note:
Ensure condensate trap is fully drained before
removal.
2.
Remove the casing front & bottom panel.
Refer to Frames 49 & 50.
3.
Swing the control box down into the servicing
position. Refer to Frame 51.
4.
Disconnect the condensate drain pipe.
5.
Remove the 2 securing screws and pull the trap
down and forward to remove.
6.
Transfer the drain pipe to the new trap and
reassemble in reverse order.
7.
When reassembling ensure the trap is full of water.
8.
Check operation of the boiler. Refer to Frames 45 &
46.
1.
Refer to Frame 57.
2.
Swing the control box into the servicing position. Refer
to Frame 51.
3.
Drain the DHW circuit. Refer to Frame 77.
4.
Unscrew the knurled retaining nut.
5.
Disconnect the in line electrical connection and
withdraw the thermistor.
6.
Reassemble in reverse order.
7.
Check operation of the boiler. Refer to Frames 45 & 46.
70
DHW THERMISTOR REPLACEMENT
ispfu9796b
4
5
SER
VICING
206091-1.pmd
26/05/2010, 16:09
50