19
INSTALLATION
ESPRIT 2 -
Installation and Servicing
FLUE OUTLET
17B SETTING THE FLUE - SIDE
Wall thicknesses of 170 to 395mm
17A SETTING THE FLUE - REAR
Wall thicknesses of 210 to 435mm
Notes.
a.
If using the extension ducts go to Frame 18.
b.
For shorter flue requirements use non telescopic B
Pack.
1.
Measure and note wall thickness X. Refer to Frame 12.
2.
Measure distance from side of boiler to inside of wall
and add to wall thickness X=L. Refer to Frame 12.
3.
Add 115mm to dimension L and set telescopic flue
length as indicated in drawing.
4.
Using a 3.5mm drill bit, drill one hole in outer air duct
taking care not to pierce plastic inner flue.
5.
Fix to length using self tappers provided.
6.
Seal outer air duct using the tape provided.
Notes.
a.
If using the extension ducts go to Frame 18.
b.
If the stand-off frame is used it is essential to add 33mm
to dimension X.
c.
For shorter flue requirements less than 210mm, use non
telescopic B Pack.
1.
Measure and note wall thickness X. Refer to Frame 12.
2.
Add 75mm to dimension X and set telescopic flue length
as indicated in drawing.
3.
Using a 3.5mm drill bit, drill one hole in outer air duct
taking care not to pierce plastic inner flue.
4.
Fix to length using self tappers provided.
5.
Seal outer air duct using the tape provided.
nm8944
X + 75
Drill hole
Adhere sealing tape
Measurement to be
taken from this point
nm8945
L + 115
Drill hole
Adhere sealing tape
Measurement to be
taken from this point
16 TERMINAL WALL SEAL ASSEMBLY / POSITIONING
Ensure lip of wall seal is positioned
over step on plastic nose of flue terminal
(
note
, s
e
a
l
i
s
c
u
t
a
w
ay
for
cl
a
rit
y)
Step
isfu9783
Wall Seal Lip
Prior to fitting the flue, the rubber terminal wall seal provided
in the flue pack MUST be fitted to the flue terminal as shown
below in Figure 1.
FIGURE 1
FIGURE 2
Once the flue is installed it is IMPORTANT that the rubber
terminal wall seal is pressed against the outside wall to
create an adequate seal between the flue and wall as
shown in Figure 2.
var9784
Rubber
Terminal
Wall Seal
206091-1.pmd
26/05/2010, 16:08
19