4.2 SEAL ASSEMBLY
ICS Pumps are supplied as standard with a flushed gland assembly. Refer to ICS or our nearest agent to determine
the most appropriate method of sealing in your specific application.
4.2.1 STUFFING BOX SEAL ASSEMBLY - Ref Fig 4
Figure 4-
Assemble Gland Seal
For longevity, ALL gland packed pumps require a reliable external water flush as detailed in Appendix A. The
standard ICS supply incorporates a Lantern Restrictor which is located at the impeller end of the stuffing box.
‘Low Flow’ lantern restrictors are available as an option, however when pumping abrasive slurries these reduce
are not as effective as the ‘Full Flow’ standard version. Refer Figure 5, 6 and 7 for arrangement options.