Fit Gland Seal over Shaft Sleeve, until it slots into the bore of Expeller Ring. Press down to compress
Packing Rings. Fit Gland Bolts to recesses in Expeller Ring, with the bolts extending through the holes
in GLAND ASSEMBLY, fit washers and nuts, and finger tighten to hold Shaft Sleeve (final adjustment
will be made when running pump). A cable tie may be used to secure bolts in position.
VIII.
Apply anti-seize to recess in Frame Plate where the Expeller Ring will sit to assist future removal. Fit
the Expeller Ring you have assembled to the Frame Plate, and tap into position with a soft mallet.
IX.
Locate Expeller Ring with the grease inlet connection at the top.
X.
Check that all Shaft O-Ring before the Sleeve is correctly positioned in groove and have not been
damaged during assembly.
XI.
Fit second Shaft O-Ring on end of sleeve protruding through Expeller Ring.
XII.
Fit Expeller to Shaft, and push to ensure there is contact of all components mounted back to the bearing
spacer.
XIII.
Fit Impeller O-Ring to groove in Expeller using thick compatible grease to ensure it does not move
when screwing on impeller.
XIV.
Ensure the shaft thread is clean and free of burrs and sharp edges. Using gloves apply anti-seize
compound liberally to Shaft thread.
XV.
Fit Grease Nipple to Expeller Ring. Apply grease to Nipple with grease gun, to charge Lantern Ring
cavity.