Your newest and most innovative supplier of global mining components
Visit our website at www.icsweargroup.com
Or contact us directly at [email protected]
8
4.
PUMP ASSEMBLY INSTRUCTIONS
Reference to a Sectional Arrangement Drawing provided by ICS for the particular pump being assembled will be
of assistance in the instructions outlined in the following sections.
All parts dismantled during pump overhaul should be inspected to determine suitability for reuse,
and identification of new parts should be checked.
Parts suitable for re-use should be cleaned and if necessary re-painted. Matching faces should be free of rust,
dirt, and burrs, and have a coating of anti-seize compound applied prior to assembly, so that the pump remains
easy to fix in future overhauls.
Small standard fasteners should preferably be replaced, and all threads coated with suitable compound (such as
anti-seize) before assembly.
Replacement of all elastomer seals (such as O rings and joint rings) is recommended at major overhauls, as
these materials usually deteriorate with use. Direct exposure to sunlight causes accelerated deterioration of
elastomers and will result in more frequent changing of parts.
4.1 FRAME ASSEMBLY
4.1.1 FITTING BEARING ASSEMBLY TO BASE – Ref Fig 1
Figure 1 -
Bearing Frame Assembly in Base.