4.1.2 FITTING FRAME PLATE AND COVER PLATE BOLTS – Ref Fig 2
Figure 2
- Assembling Frame Plate and Cover Plate Bolts
(i)
Apply anti-seize compound to the recesses in the base where the Frame Plate spigot engages. Fit Frame
Plate to Base, ensuring that the Frame Plate locating spigot engages with the corresponding Base arms.
For pumps 6x4 and larger, Frame Plates are provided with either radially tapped holes for eyebolts or
lifting lugs to assist fitting.
(ii)
Insert Frame Plate Studs or Frame Plate Bolts, depending on pump size. Fit and fully tighten nuts.
Depending on the pump size, the Frame Plate is bolted externally using studs. whilst others use bolts
which are inserted from within the Frame Plate. In most pump sizes, the Frame Plate can be rotated to
provide eight alternative angular discharge positions.
(iii)
Ensure the cover plate bolts are clean, and remove any burrs. Cover threads with anti-seize. Fit Cover
Plate Bolts Through Frame Plate lugs.