A-42
A4
The auto_eos_mode procedure is used to read/modify the automatic EOS on
EOI mode. If the autoEos mode is TRUE, then an EOS character will be sent
with EOI.
struct Auto_Eos_Parms {
unsigned
int
action;
unsigned
int
autoEos;
};
struct Auto_Eos_Resp {
unsigned
int
error;
unsigned
int
autoEos;
};
Auto_Eos_Resp auto_eos_mode (Auto_Eos_Parms) = 17;
The action value determines whether the client wishes to execute a read of the
current setting, or a modification of the current value.
action = 0 = read of current value
action = 1 = modify current value
If the action value is other than 0 or 1, then an error value of 5 is returned.
If the RPC message is of insufficient length to satisfy the required length, an
error value of 1 is returned.
The autoEos mode must be either 0 or 1. An error of 5 is returned and the current
automatic EOS mode is unchanged if autoEos is determined to be invalid.
The returned Auto_Eos_Resp structure will always contain the current automatic
EOS mode, irrespective of the error value.
error Meaning
0
No error
1
Syntax error
5