2-22
2
2.12 9099
RACK MOUNTING INSTRUCTIONS
The Model 9099 is held in its rack mounting kit with a winged-'U' shaped bracket.
Perform the following steps to install a 9099 in a rack mounting kit:
1.
Hold the 9099 at a 30 degree nose down angle and place the front bezel
through the rack mount kit from the rear of the kit. Push it forward
through the opening until the rubber feet line up with the holes in the
rack mounting kit. Push the unit down until it rests flat on the kit and
the feet are in the four holes.
2.
Repeat step 1 for a second unit if two units are being held in one rack
mounting kit.
3.
Align the unit(s) so the bezels are parallel with the front of the rack
mount kit and protrude equally through the front panel of the rack
mounting kit.
4.
Set the bracket so its two holes line up with the holes in the rack mount-
ing kit extrusion. Use the supplied 4-40 screws to hold the bracket to
the extrusion. Do not overtighten.
5.
Use the supplied 10-32 screws to bolt the rack mounting kit into the
rack.