Command 2: Read P.V. Current and Percentage of Range
Request data bytes: none
Response data bytes: 2+8 = 10
Index
Format
Description
Byte 0
uint8
Response code 1
Byte 1
uint8
Response code 2
Byte 2~5
float
Primary Variable Current
Byte 6~9
float
Primary Variable Percentage of Range
Command 3: Read Dynamic Variables and P.V. Current
Request data bytes: none
Response data bytes: 2+24 = 26
Index
Format
Description
Byte 0
uint8
Response code 1
Byte 1
uint8
Response code 2
Byte 2~5
float
Primary Variable Current
Byte 6
uint8
Primary Variable Unit code
Byte 7~10
float
Primary Variable
Byte 11
uint8
Secondary Variable Unit code
Byte 12~15
float
Secondary Variable
Byte 16
uint8
Tertiary Variable Unit code
Byte 17~20
float
Tertiary Variable
Byte 21
uint8
4th Variable Unit code
Byte 22~25
float
4th Variable
Command 6: Write Polling Address
Request data bytes: 1
Index
Format
Description
Byte 0
uint8
Polling Address
Response data bytes: 2+1 = 3
Index
Format
Description
Byte 0
uint8
Response code 1
Byte 1
uint8
Response code 2
Byte 2
uint8
Polling Address