Item
Description
Default
Packing Length (bytes)
When the input serial data length reaches to the
value, it will be sent out.
Settings range: 0 ~ 1024; Disabled: 0.
0
Serial Ending Chars
(Number[,char1][,char2])
The tDS-700 outputs an Ethernet packet immediately
after the ending-chars pattern is identified from the
incoming serial data. The number of ending-chars can
be 0 (disabled), 1 or 2 chars.
Disabled=0;
1 char:
1,0x0D
;
2 chars:
2,0x0D, 0x0A
0
Timeout Between Chars (ms)
Set the waiting time after Rx of the response sent
from the device. If the device does not respond within
the timeout value, the tDS-700 will process this
response.
Settings range: 10 ~ 65535; Disabled: 0.
10
Pair-Connection Settings (Client/Server Mode)
Application Mode
Server
Client
Remote Server IP
-
IP address of the remote device
Remote TCP Port
-
TCP Port number of the remote
device
Submit
Click this button to save the revised settings to the tDS-700.
Note
The more detailed information regarding pair-connection applications settings, please
refer to the section
5.4 “
Pair-Connection Applications".