Setting the input signals with digital filter:
There are five check box (FE0 ~ FE4) to set the input signals to use digital filter.
FE0 is for Emg. Signal (EMGN), +/- limits (LMT
±
), Home limit(STOP1), and Near
Home limit(STOP0)
FE1 is for Encoder Z phase signal (STOP2)
FE2 is for Servo In-position signal (INP) and Servo alarm signal (ALM).
FE3 is for +/- external pulse input(EXP+/EXP-).
FE4 is for IN3 signal.
Related Function: i8092_set_filter().
9. INT Factor Settings
:
Seven kinds of interrupt event settings are provided in i-8092F motion module
1. Position Counter >= Comp- Counter: Position counter is greater than or equal
to the Negative-comparator.
2. Position Counter < Comp- Counter: Position counter is less than the
Negative-comparator.
3. Position Counter >= Comp+ Counter: Position counter is greater than or equal
to the Positive -comparator.
4. Position Counter < Comp+ Counter: Position counter is less than the Positive
-comparator.
5. End of Constant Speed Drive: The interrupt is triggered when Constant-speed
driving is completed.
6. Start of Constant Speed Drive: The interrupt is triggered when Constant-speed
driving is started.
7. Drive Finished: The interrupt is triggered when the specific axis is stopped.
Related Function: i8092_set_int_factor().
10. Function of Buttons :
To BasicOperation: The shortcut to Basic Operation Dialog.
To Interpolation: The shortcut to Interpolation Dialog.
LoadConfig: Loads the pre-defined configuration.
SaveConfig: Saves the configuration of all available i8094/F modules.
Return
:
Returns to initial frame.
11. Status Bar :
Displays the Error Status