Parameters
iSlot
Specific slot number (0 - 7), except range of slot is number 1 ~ 8 for LinPAC.
iChannel
Specifies the channel number
For I-8017HW / I-8017HCW / I-8017DW / I-9017 => 0 ~ 8 in differential method; 0 ~ 15 in
single-ended method.
For I-9017-15 => 0 ~ 14 in differential method; 0 ~ 29 in single-ended method.
For I-9017C-15 => always 0 ~ 14.
iGain
Specifies the input range
0: +/- 10.0V
1: +/- 5.0V
2: +/- 2.5V
3: +/- 1.25V
4: +/- 20mA
* iValue
[Output] the analog input value in hexadecimal format.
Return Values