I-8017/I-9017 Series I/O Module User Manual
V3.0.3
P.43
3.5.
i8017H_GetSingleEndJumper / pac_i8017HW_GetSingleEndJumper
This function is used to read whether the jumper is set to either Differential or Single-ended mode.
Syntax
For MiniOS7
short pac_i8017HW_GetSingleEndJumper(int iSlot, short* selectJumper);
For Windows (CE and WES)
short pac_i8017HW_GetSingleEndJumper(int iSlot, short* selectJumper);
For Linux
short I8017_GetSingleEndJumper(int iSlot, short* selectJumper);
// for LinPAC-8000
short I9017_GetSingleEndJumper(int iSlot, short* selectJumper);
// for LP-9000, LX-9000
Parameters
iSlot
Specific slot number (0 - 7), except range of slot is number 1 ~ 8 for LinPAC.
* selectJumper
[Output] The status of module.
0: Differential Mode
1: Single-ended Mode
Return Values
Refer to Appendix A: “Error Code” for more details.
Summary of Contents for I-8017 Series
Page 14: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 14 1 2 Pin Assignments 1 2 1 I 8017HW ...
Page 15: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 15 1 2 2 I 8017HCW ...
Page 16: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 16 1 2 3 I 8017DW ...
Page 17: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 17 1 2 4 I 9017 ...
Page 18: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 18 1 2 5 I 9017 15 ...
Page 19: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 19 1 2 6 I 9017C 15 ...
Page 26: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 26 1 5 3 I 9017C 15 ...
Page 55: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 55 ...
Page 83: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 83 Click Restore Defaults button ...