IC
L
ive Users Manual - Models ICL-R & IC215S-R
SERVICING and TROUBLE SHOOTING (cont)
57
RHAON Network Manager
To activate the RHAON Network Manager open RHAION and select Network Manager from the File pull down menue.
The Network Manager will scan the Ethernet network, list all the CobranNet devices it found on the network and identify them by name, MAC
and IP numbers. It also checks for communication errors (dropped packets). Any errors detected will be counted and listed in the Error column
along with a code number identifying the type of error. Notice that the error count continues to increase as the Network Manager continues to
scan the network for errors. In the example shown below the ICL-FR Left array obviously has a problem while two other devices are showing
an occasional glitch.
The Age column shows in milliseconds how long it has been since the device was checked
by the Network Manager. It is normal for the numbers to fluctuate rapidly.
The Startup IP column will show the device’s Startup IP address, if a startup IP was as-
signed to it. To assign a startup ID to a single device, double right click on one of the device’s
listing to open the dialog box show to the right. It allows you to assign a specific IP address (a
startup IP) to that device. Startup IP addresses will not be lost in case of a power disruption
to the device. You can also assign Startup IP addresses to all the devices at one time by
clicking on the Command pull down menu and selecting Reset all IP Addresses as Startup.
The Error Code Reference Guide is accessed from the RHAON Help pull down menu.