TITAN HD USER MANUAL
88
8-21-21 Factory Reset the Device
If measurements are skewed the user should try adjusting the emissivity and
ambient temperature before attempting to restore factory setting. Restore
default settings as follows:
1.
Using the touchscreen, tap the settings icon to open the Settings Menu.
2. Tap the System Settings icon:
3. Press-and-hold on the touchscreen; then, drag to scroll through the options.
4. Tap Factory Reset. A pop-up appears.
5. Tap Confirm to perform a factory reset. Tap Cancel to cancel changes.
The device restarts several times during the reset process. Have patience
as this operation can take several minutes. After the final restart use the
touchscreen to select a device language and establish date and time
settings. The user interface boots after selection is complete.
PERFORMING A FACTORY RESET ERASES CUSTOMIZED USER
CONFIGURATIONS STORED ON THE DEVICE AND RESTORES THE ORIGINAL
DEFAULT SETTINGS PROGRAMMED BY THE MANUFACTURER. THE PROCESS
CANNOT BE UNDONE.
PERFORMING A FACTORY RESET WILL NOT FORMAT THE MEMORY CARD
HOWEVER USERS MAY WISH TO REMOVE THE MEMORY CARD BEFORE
ATTEMPTING A FACTORY RESET OF THE DEVICE.
THE USER MAY NEED TO ADJUST THE DEVICE SETTINGS OR RESTART THE
DEVICE TO OBTAIN ACCURATE READINGS.
2.
5.