Electrical System
• Harvest cycle not initiated electrically
• Compressor electrically non-operational
• Restricted condenser air flow
• High inlet air temperature (110°F/43.3°C max.)
• Condenser discharge air re-circulation
• Dirty condenser fins
• Defective fan motorDirty condenser
Refrigeration System
• Non-Icetro components
• Improper refrigerant charge
• Defective compressor
• Non-condensible in refrigeration system
• Plugged or restricted high side refrigerant lines or
component
• Defective hot gas valve