Freeze Cycle Discharge Pressure High Checklist
Improper Installation
•
Refer to “Installation/Visual Inspection
Checklist” on page 32.
Air Condenser
•
Dirty condenser filter.
•
Dirty condenser fins.
•
High inlet air temperature.
•
Condenser discharge air recirculation.
•
Defective fan cycling control.
•
Defective fan motor.
•
Defective headmaster valve (Remote).
Water Condenser
•
Low water pressure [20 psig (138 kPa) min.].
•
High inlet water temperature (90°F/32°C max.).
•
Dirty condenser.
•
Dirty/Defective water regulating valve.
•
Water regulating valve out of adjustment
Other
•
Overcharged.
•
Non-condensable (air) in system.
•
Wrong type of refrigerant.
•
Non-Icetro components in system.
•
High side refrigerant lines/component restricted.
85
Summary of Contents for IM Series
Page 1: ...Revision Date 1 24 22 IM Series Air Water Remote Ice Machines Technician s Handbook ...
Page 2: ......
Page 3: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 9: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 15: ...THIS PAGE INTENTIONALLY LEFT BLANK 14 ...
Page 17: ...How to Read a Serial Number Full Serial Number 16 ...
Page 35: ...THIS PAGE INTENTIONALL Y LEFT BLANK 34 ...
Page 48: ...Flexible Numeric Display FND Functions 47 ...
Page 93: ...THIS PAGE INTENTIONALLY LEFT BLANK 92 ...
Page 106: ...Testing the water level sensor Before S N Starting With VC 105 ...
Page 134: ...SERVICE REMOTE RECOVERY EVACUATION CONNECTIONS 133 ...
Page 145: ...THIS PAGE INTENTIONALLY LEFT BLANK 144 ...
Page 155: ...THIS PAGE INTENTIONALLY LEFT BLANK 154 ...
Page 157: ...Wiring Diagram 156 ...
Page 158: ...PCB Layout 157 ...
Page 159: ...PCB Dip Switches 158 ...
Page 161: ...SPACE FOR TECHNICIAN S NOTES ...
Page 162: ...SPACE FOR TECHNICIAN S NOTES ...
Page 163: ...SPACE FOR TECHNICIAN S NOTES ...
Page 164: ...SPACE FOR TECHNICIAN S NOTES ...
Page 165: ......