Sequence of Operation
SELF CONTAINED AIR OR WATER COOLED
NOTE: The 'ICE/OFF/WASH' switch must be in the 'ICE'
position and the water curtain must be in place on the
evaporator before the ice machine will start.
Initial Start-Up or Start-Up
After Automatic Shutdown
1. Water Fill
Water inlet valve energizes to allow the water trough to
fill, until water reaches the low-level probe on the water
sensor probe.
2. Water Flush
The dump valve and water pump are then energized to
discard the remaining water in the trough for 20 seconds.
The dump valve and water pump is de-energized and the
water inlet valve energizes a second time to allow the
water trough to fill, until water reaches the high-level
probe on the water level sensor.
3. Refrigeration System Equalization and Start-Up
The hot gas valve energizes for 10-20 seconds to allow for
pressure equalization and to reduce compressor starting
torque.
The PCB supplies control voltage to the contactor,
which energizes the compressor. At the same time, the
PCB sends power to the condenser fan motor.
NOTE: The fan motor is wired through a fan cycle
pressure control and will not cycle on until/unless the
compressor is running.
51
Summary of Contents for IM Series
Page 1: ...Revision Date 1 24 22 IM Series Air Water Remote Ice Machines Technician s Handbook ...
Page 2: ......
Page 3: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 9: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 15: ...THIS PAGE INTENTIONALLY LEFT BLANK 14 ...
Page 17: ...How to Read a Serial Number Full Serial Number 16 ...
Page 35: ...THIS PAGE INTENTIONALL Y LEFT BLANK 34 ...
Page 48: ...Flexible Numeric Display FND Functions 47 ...
Page 93: ...THIS PAGE INTENTIONALLY LEFT BLANK 92 ...
Page 106: ...Testing the water level sensor Before S N Starting With VC 105 ...
Page 134: ...SERVICE REMOTE RECOVERY EVACUATION CONNECTIONS 133 ...
Page 145: ...THIS PAGE INTENTIONALLY LEFT BLANK 144 ...
Page 155: ...THIS PAGE INTENTIONALLY LEFT BLANK 154 ...
Page 157: ...Wiring Diagram 156 ...
Page 158: ...PCB Layout 157 ...
Page 159: ...PCB Dip Switches 158 ...
Page 161: ...SPACE FOR TECHNICIAN S NOTES ...
Page 162: ...SPACE FOR TECHNICIAN S NOTES ...
Page 163: ...SPACE FOR TECHNICIAN S NOTES ...
Page 164: ...SPACE FOR TECHNICIAN S NOTES ...
Page 165: ......