ANALYZING WHY AN ERROR CODE STOPPED THE ICE
MACHINE (CONTINUED)
ERROR CODE #17 (WATER-COOLED ONLY)
Error Code 17 - If excessive cooling is detected when
the machine is FULL or OFF, the machine will continue to
run, but display Er_17.
Possible cause checklist
Water System
•
Water regulating valve is faulty or stuck
open.
•
Liquid-line thermistor is open or shorted.
NOTE: Temporarily disconnecting the
thermistor from the PCB will allow the
machine to continue to make ice even if the
error continues to occur.
75