34
We Think of Customer Satisfactio
n
Item
Display
Description
Initial Drain Time
1. Adjust initial drain time.
2. Range: oFF ~ 30 sec. (by 1 seconds)
Drain Time after
Harvest
1. Adjust drain time after harvest.
2. Range: oFF ~ 30 sec. (by 1 seconds)
Drain Time after Ice
Making
1. Adjust drain time after making ice.
2. Range: oFF ~ 30 sec. (by 1 seconds)
Water Supply Delay
Time
1. Adjust the delay time after detecting high water level
(0.5 seconds).
2. Range: 0 ~ 30 sec. (by 1 second)
3. Maximum water supply time: 5 minutes
4. If high water level has already been detected
when the water is supplied, the delay is not applied.
Harvest Assist
Temperature
(Optional)
1. With hot gas, run the sub-motor if the preset
condenser temperature is exceeded.
2. Range: -49 ~ 59℃ (by 1℃)
Pump Standby Time
during Ice Making
(Optional)
1. Stops pump for the preset time when the water
temperature in the water vessel turns to 0℃.
2. Range: 0 ~ 120 sec. (by 1 second)
Temperature
Selection
1. Choose Celsius or Fahrenheit.
2. Display: c, F
Water Vessel
Water Temperature
(Optional)
1. Displays current water temperature in the water vessel.
2. Display Range: -49 ~ 59℃ (by 1℃)
Condenser Outlet
Temperature
1. Display current temperature at the condenser outlet.
2. Display Range: 0 ~ 100℃ (by 1℃)
Evaporator Inlet
Temperature
1. Display current temperature at the evaporator inlet.
2. Display Range: -49 ~ 59℃ (by 1℃)
Evaporator Outlet
Temperature
1. Display current temperature at evaporator outlet.
2. Display Range: -49 ~ 59℃ (by 1℃)
[ Display and How to Use ]