35
Caution
7. Requirements for Freeze Protection
Removal of Water from Condenser (Water-Cooled Type)
1. Turn off the power switch on the top right side of the main unit and earth leakage
breaker on the rear side and pull the power cord from the outlet.
2. Close the faucet and ensure that hoses are removed from the cooling water supply
unit and cooling water drain unit on the rear side of the product.
3. Turn the handle for removing water for freeze protection to the 9 o'clock
position (counterclockwise) to remove the water staying inside the condenser.
4. Remove water and turn the handle valve to the 12 o'clock position (clockwise)
to close, and reconnect supply hose and drain hose.
Power Switch
Cooling Water Supply
Cooling Water Drain
Hand Valve
Drain for Water
Remaining in Condenser
< Front Panel of Main Body >
< Rear Side of Main Body >
[ Cooling Water Supply and Drain on the Rear Side of Main Unit ]
Connect cooling water supply
and cooling water drain
Open hand valve
Counterclockwise
Clockwise
Close hand valve
Remove water
from condenser
Water from the cooling part
If you do not close the hand valve after removing water, it will not make ice but release water
next time you use the product.
REMOVED