background image

8

Funcons & Operaon

 

08

Press             the buon to acvate a 3 minute deodorizer cycle.
Press             again to end the deodorizer cycle early.

Deodorizer

Electric power consumpon is lile and use the LED Nightlight funcon without care about the electric charge.

LED Nightlight 

USING THE REMOTE:  

Press the             buon at the top of the remote to acvate the flush.  This method is 

funconal regardless of the Auto Flush sengs.

USING THE SEAT CONTROLS: 

 

In the event of a power outage or remote malfuncon, the flush can be acvated 

using the flush buons located on the right side of the seat when facing the toilet (see image below). 

Manual Flush Opons

Auto Flush

To set the unit to Auto Flush mode, press and hold the          buon for at least 4 seconds, then release.

When the Auto Flush mode is set, the toilet will flush automacally when it detects a user has vacated the 
seat a…er sing for 5 seconds or more. 

In the event of a power outage, the Auto Flush will not operate. See below for instrucons on how to flush 
manually.

To deacvate Auto Flush mode, press and hold the          buon for at least 4 seconds, then release. The 
unit should no longer flush automacally.

Manual Flush button

1

2

Hold the bu on towards the front of the bowl (bu on 
1)  for  4  seconds

  to  acvate  a  rim  wash.    Then, 

hold 

bu on towards the rear of the bowl (bu on 2) for 4 
seconds

 to acvate the siphon jet to clear any waste.  

Then, 

hold  bu on  1  for  an  addional  4  seconds

  to 

acvate a second rim wash to refill the bowl. 

Note: 

the 

buons on the bowl are not labeled - numbers shown 
on the image to the le… are for instruconal reference 
only.

Acvate the LED NIGHTLIGHT by pressing the        buon on the remote control. The nightlight will turn on 
only when the sensor reads a dim or dark environment, and will automacally shut off in a lit room.

Summary of Contents for S-20 RF

Page 1: ...and use Please save this instruc on manual and place in an easily accessible loca on External appearance and specifica ons are subject to change for improvement of product without no ce Muse iWash CS...

Page 2: ...persons including children with reduced physical sensory or mental capabilities unless under the supervision of a responsible adult Use this product only for its intended use as described in this man...

Page 3: ...wer cord and call Icera Customer Service for assistance Using a malfunctioning seat may be a fire and or electric shock hazard Do not dismantle repair or alter the unit unless under the instruction of...

Page 4: ...n Main unit 3 Seat Control Panel Floor Bolt Covers Non sittable Seat Lid Manual Flush Buttons Deodorizer Vent Rear Wash Spray Warm Air Dryer Outlet Front Wash Spray In bowl LED Nightlight Seat Sensor...

Page 5: ...4 Parts Identification Light sensor Control Panel Remote control Top Front 04...

Page 6: ...removed to expose 1 2 MIP threads x1 GFCI receptacle x1 wired in wall and tested Bowl to flange gasket x1 a waxless ring is recommended although a bee s wax ring may be used Pair of 2 1 2 long toilet...

Page 7: ...ill cease and the nozzle will return to its res ng positon You can supplement by wiping gently with toilet paper if desired When si ng on the seat sit in the center to ensure the seat sensor detects t...

Page 8: ...adjust the water pressure it will default to the last used se ng Nozzle Posi on Adjustment Water Pressure Adjustment Press on the remote to adjust the temperature of the warm air If you choose not to...

Page 9: ...flush automa cally when it detects a user has vacated the seat a er si ng for 5 seconds or more In the event of a power outage the Auto Flush will not operate See below for instruc ons on how to flush...

Page 10: ...G USER PRESETS Quickly press and release the user preset desired to ac vate A short beep will sound when the user preset is ac vated STANDARD In Standard mode the seat temperature will be maintained a...

Page 11: ...your installation INSTALLATION STEPS The centerline of the floor drain is to be 12 from finished back wall Do not includethethicknessofanybaseboardmoldingwhentakingthismeasurement The centerline of th...

Page 12: ...Recommend 2 workers when lifting up the ceramic flange Drain Bolts Wax seal Flange or 11 11 3 Unbox the bowl Viewing from the back you ll notice 2 factory installed braided stainless steel lines One...

Page 13: ...the ceramic flange Drain Bolts Wax seal Flange or 11 12 4a Unbox the bidet seat and the rest of the bowl Hand tighten the bowl jet supply line to the 1 2 plastic inlet on the left bottomside of the s...

Page 14: ...the flange Ceramic is heavy Recommend 2 workers when lifting up the ceramic flange Drain Bolts Wax seal Flange or 11 13 5a Install seat anchors included in bowl deck holes 5b Insert plastic hold down...

Page 15: ...is heavy Recommend 2 workers when lifting up the ceramic flange Drain Bolts Wax seal Flange or 11 14 6a Hand tighten 1 2 brass adapter to the water filter both included 6b Hand tighten filter to 3 4...

Page 16: ...lean when fixing the flange Ceramic is heavy Recommend 2 workers when lifting up the ceramic flange Drain Bolts Wax seal Flange or 11 15 8 GENTLY align bowl over drain flange guiding mounting bolts th...

Page 17: ...e Drain Bolts Wax seal Flange or 11 16 10 Hand tighten 1 2 supply hose to angle stop Use a wrench to tighten fully Ensure supply hose is not kinked or awkwardly bent The hose should appear as in the p...

Page 18: ...gain a er about 5 minutes The warm air dryer is not warm Is the DRY temperature set at low Adjust the temperature se ng to a higher level AUTO FLUSH does not operate Is there power to the outlet Use M...

Page 19: ...he flush is complete Make sure the plug is securely connected Unplug the unit and plug another device into the outlet to make sure there is power Check points Check the followings details before calli...

Page 20: ...p Adjustment Water Pressure Adjustment Front Wash Rear Wash Direct connec on to the water supply Thermal Fuse Thermostat Thermal Fuse Thermal Fuse Bi metal Water Flow Rate AmbientTemperatureRange Seat...

Page 21: ...channel in homes where two or more units are installed in close proximity If two units are being ac vated by a single remote follow the steps below to adjust the frequency on one remote 1 Turn the uni...

Page 22: ...sure adjustment bu on again The LED light should move on the remote which indicates the change to the next channel You can select any of the frequency channels shown below except for Channel 1 which i...

Page 23: ...ective product or installation costs of replacement pieces Excluded from coverage through this warranty are items used as plumbing fixture trim various fittings toilet bowl seats and tank flushing mec...

Page 24: ...hanges in finish scratching staining and other effects from chemical use water and atmospheric conditions are not considered manufacturing defects but are considered normal wear and tear Variations in...

Page 25: ...Warranty ICERA USA P O Box 4238 Westminster CA 92684 P 855 444 2372 E service icerausa com 6522 0482 00 Rev 0...