background image

9

Funcons & Operaon

The nozzle system is both sanitary and effecve. The self-cleaning nozzle has separate secons for the front and rear 
wash  cycles.  It  is  internally  treated  with  an  anbacterial  nano-silver  compound  for  added  sterility.  The  nozzle  is 
automacally sanzed before and aer each use.

The nozzle should also be cleaned manually periodically.  Using the control panel located on the seat, press the               
      REAR WASH and           FRONT WASH buƒons at the same me.  Clean the nozzle manually with a so brush. 
Press the STOP buƒon on the control panel to return the nozzle to its resng posion.  The self-cleaning funcon 
will then operate.

The seat temperature will automacally lower when set to the highest se†ng if the seat is occupied for more than 30 

minutes to protect the user against low-grade burns.

Burn Protecon

Nozzle Cleaning

09

User Presets

SAVING USER PRESETS: 

Set water pressure and temperature, nozzle posion, dryer temperature and seat temperature

to the desired se†ngs, then hold the        buƒon for 4 seconds to save. A long beep will sound once the se†ngs are saved. 
Repeat for       .    

ACTIVATING USER PRESETS:  

Quickly press and release the user preset desired to acvate. A short beep will sound 

when the user preset is acvated. 

STANDARD: 

 In Standard mode, the seat temperature will be maintained at the se†ng last selected by the user.

AUTO:

 Press the          POWER MODE buƒon on the seat control panel to acvate the AUTO power saving mode. In 

AUTO  power  saving  mode,  the  seat  temperature  will  be  maintained  at  86°  F  (30°  C).  Once  occupied,  the  seat 
temperature is fully adjustable via the remote control.

ECO:

  For even greater energy-efficiency, press the        POWER MODE buƒon on the seat control panel twice to 

acvate the ECO power saving mode. In ECO power saving mode, the seat will be maintained at room temperature. 
When a light is turned on in the bathroom, the seat will switch to AUTO power saving mode and revert back to ECO 
power saving mode when the light is no longer detected. 

Power Saving Modes

Power Saving Modes

Power On/Off

To turn the unit off, hold the           POWER MODE buƒon on the seat panel for 4 seconds (unl the LED lights shut off).
To turn the unit on, press any buƒon on the remote except the water, dryer and nozzle adjustment buƒons.

Power On/Off

In the event of a power outage or failure, the temp. and pressure se†ngs will default to the last used se†ngs when the 
seat is powered on again.

Summary of Contents for S-20 RF

Page 1: ...and use Please save this instruc on manual and place in an easily accessible loca on External appearance and specifica ons are subject to change for improvement of product without no ce Muse iWash CS...

Page 2: ...persons including children with reduced physical sensory or mental capabilities unless under the supervision of a responsible adult Use this product only for its intended use as described in this man...

Page 3: ...wer cord and call Icera Customer Service for assistance Using a malfunctioning seat may be a fire and or electric shock hazard Do not dismantle repair or alter the unit unless under the instruction of...

Page 4: ...n Main unit 3 Seat Control Panel Floor Bolt Covers Non sittable Seat Lid Manual Flush Buttons Deodorizer Vent Rear Wash Spray Warm Air Dryer Outlet Front Wash Spray In bowl LED Nightlight Seat Sensor...

Page 5: ...4 Parts Identification Light sensor Control Panel Remote control Top Front 04...

Page 6: ...removed to expose 1 2 MIP threads x1 GFCI receptacle x1 wired in wall and tested Bowl to flange gasket x1 a waxless ring is recommended although a bee s wax ring may be used Pair of 2 1 2 long toilet...

Page 7: ...ill cease and the nozzle will return to its res ng positon You can supplement by wiping gently with toilet paper if desired When si ng on the seat sit in the center to ensure the seat sensor detects t...

Page 8: ...adjust the water pressure it will default to the last used se ng Nozzle Posi on Adjustment Water Pressure Adjustment Press on the remote to adjust the temperature of the warm air If you choose not to...

Page 9: ...flush automa cally when it detects a user has vacated the seat a er si ng for 5 seconds or more In the event of a power outage the Auto Flush will not operate See below for instruc ons on how to flush...

Page 10: ...G USER PRESETS Quickly press and release the user preset desired to ac vate A short beep will sound when the user preset is ac vated STANDARD In Standard mode the seat temperature will be maintained a...

Page 11: ...your installation INSTALLATION STEPS The centerline of the floor drain is to be 12 from finished back wall Do not includethethicknessofanybaseboardmoldingwhentakingthismeasurement The centerline of th...

Page 12: ...Recommend 2 workers when lifting up the ceramic flange Drain Bolts Wax seal Flange or 11 11 3 Unbox the bowl Viewing from the back you ll notice 2 factory installed braided stainless steel lines One...

Page 13: ...the ceramic flange Drain Bolts Wax seal Flange or 11 12 4a Unbox the bidet seat and the rest of the bowl Hand tighten the bowl jet supply line to the 1 2 plastic inlet on the left bottomside of the s...

Page 14: ...the flange Ceramic is heavy Recommend 2 workers when lifting up the ceramic flange Drain Bolts Wax seal Flange or 11 13 5a Install seat anchors included in bowl deck holes 5b Insert plastic hold down...

Page 15: ...is heavy Recommend 2 workers when lifting up the ceramic flange Drain Bolts Wax seal Flange or 11 14 6a Hand tighten 1 2 brass adapter to the water filter both included 6b Hand tighten filter to 3 4...

Page 16: ...lean when fixing the flange Ceramic is heavy Recommend 2 workers when lifting up the ceramic flange Drain Bolts Wax seal Flange or 11 15 8 GENTLY align bowl over drain flange guiding mounting bolts th...

Page 17: ...e Drain Bolts Wax seal Flange or 11 16 10 Hand tighten 1 2 supply hose to angle stop Use a wrench to tighten fully Ensure supply hose is not kinked or awkwardly bent The hose should appear as in the p...

Page 18: ...gain a er about 5 minutes The warm air dryer is not warm Is the DRY temperature set at low Adjust the temperature se ng to a higher level AUTO FLUSH does not operate Is there power to the outlet Use M...

Page 19: ...he flush is complete Make sure the plug is securely connected Unplug the unit and plug another device into the outlet to make sure there is power Check points Check the followings details before calli...

Page 20: ...p Adjustment Water Pressure Adjustment Front Wash Rear Wash Direct connec on to the water supply Thermal Fuse Thermostat Thermal Fuse Thermal Fuse Bi metal Water Flow Rate AmbientTemperatureRange Seat...

Page 21: ...channel in homes where two or more units are installed in close proximity If two units are being ac vated by a single remote follow the steps below to adjust the frequency on one remote 1 Turn the uni...

Page 22: ...sure adjustment bu on again The LED light should move on the remote which indicates the change to the next channel You can select any of the frequency channels shown below except for Channel 1 which i...

Page 23: ...ective product or installation costs of replacement pieces Excluded from coverage through this warranty are items used as plumbing fixture trim various fittings toilet bowl seats and tank flushing mec...

Page 24: ...hanges in finish scratching staining and other effects from chemical use water and atmospheric conditions are not considered manufacturing defects but are considered normal wear and tear Variations in...

Page 25: ...Warranty ICERA USA P O Box 4238 Westminster CA 92684 P 855 444 2372 E service icerausa com 6522 0482 00 Rev 0...

Reviews: