background image

Serious Connections

TM

ICCONS™ GAS TOOL GT-3 & GT-3ST USER MANUAL

14

5 - Parts List

Summary of Contents for GT-3

Page 1: ...USER MANUAL Serious Connections TM GT 3 GT 3ST GAS TOOL...

Page 2: ...ecified by the manufacturer If the tool is weakened or damaged by Punching or engraving Modification not authorized by the manufacturer Guiding against templates made of hard material Dropping or push...

Page 3: ...s Exhaust gases in a confined space can be hazardous Do not use the tool outside in the rain or where excessive moisture in present Keep the tool from heat sources as the pressurized fuel cell could b...

Page 4: ...casualty become unconscious or breathing does not quickly return to normal summon urgent medical assistance If gas gets into the eyes they should be flushed out with copious amounts of water Skin cont...

Page 5: ...r a long time Recharge it in each 3 months can help to compensate the self discharged and keep the battery in a good condition The charging systems should store at a place out of reach of children Chi...

Page 6: ...Concrete 2 6mm Steel Plate to Hard Concrete 3 0mm step With changeable nose piece systems users are allowed to shoot for different purpose Please consult local agents for further details Only those f...

Page 7: ...remain alight 5 After charging unplug the charger from the power source If both lights are blinking in same pace remove the battery cartridge and plug again If this happens continuously the battery ca...

Page 8: ...r and create hazards to users and bystanders E Installing and removing fuel cell Caution Make sure the trigger is not held while inserting fuel cell Empty fasteners in the magazine before installing f...

Page 9: ...amming of pins could be evident if users cannot drive the fasteners properly try following steps in subsequent order Caution Place the tool on flat surface prior to releasing the magazine magazine may...

Page 10: ...ean the mesh with brush or air 3 Put the back cover on the machine and fasten with four screws NOTE Do not attempt to use water to clean the mesh The cover and mesh must be dry when operating the tool...

Page 11: ...by Authorized Serviceman TROUBLESHOOTING Normal Stage Of Operation Possible reasons Services Battery is discharged Charge Battery Cell Possible reasons Services Battery is loose or contacts are bent...

Page 12: ...not cycle fan runs Possible reasons Services Fuel Cell is empty Replace Fuel Cell Spark does not occur Contact authorized serviceman for repair SYMPTOM 4 Fail to drive fasteners Possible reasons Servi...

Page 13: ...t stable SYMPTOM 4 Unstable performance Possible reasons Services Built up dirt and debris inside cylinder Contact authorized serviceman for repair SYMPTOM 5 Diminishing power Possible reasons Service...

Page 14: ...Serious Connections TM ICCONS GAS TOOL GT 3 GT 3ST USER MANUAL 14 5 Parts List...

Page 15: ...S TRACK ST short 25 NB1100 SOCKET SCREW Blue 242 81 NB1ZA0 FOLLOWER 26 NB1290 METAL WASHER 82 NB1910 TRACK CAP 27 NB1170 LOCKNUT 83 NB1800 TRACK CONNECTOR 28 NB1380 METAL WASHER 84 NB1160 SOCKET SCREW...

Page 16: ...ong South Victoria 3175 Australia Passing on and duplication of this document exploitation and disclosure of its contents are forbidden unless expressly approved Violations render the offender liable...

Reviews: