SYMPTOM 3

Red and green LEDs on charger are 
blinking simultaneously.

SYMPTOM 1

Fan does not run.

  

SYMPTOM 2

Fan does not run, or runs slower than 
normal.

Possible 
reasons

Services

Battery is hot. Remove battery from 

charger and allow to 
cool. Inspect battery 
charger and cartridge.

Possible 
reasons

Services

Battery 
damaged 
or cycle life 
exhausted.

Replace Battery.

Possible 
reasons

Services

Battery is not 
charged.

Charge Battery 
according to 
Operating Manual.

Battery 
Terminals 
or Handle 
battery 
contacts are 
oily, dirty, or 
corroded.

Clean Battery Cell 
terminals Clean 
Handle Battery Cell 
contacts as required.

There is 
electrical 
short 
somewhere.

The tool must 
be looked into 
by Authorized 
Serviceman.

TROUBLESHOOTING

Normal Stage Of Operation

Possible 
reasons

Services

Battery is 
discharged.

Charge Battery Cell.

Possible 
reasons

Services

Battery is 
loose or 
contacts are 
bent.

Snap battery back 
into its locked 
position. Bend 
contacts back into 
proper position.

TROUBLESHOOTING

Pre-Combustion/Combustion Stage of 

Operation

Possible 
reasons

Services

Lockout Bar is 
stuck in lock-
out position.

Check if there is not 
enough pins in the 
channel, load extra 
pins according to 
Operating Manual.

The nose 
piece is bent, 
or the channel 
is stuck with 
dirt.

Inspect if the nose 
piece and channel is 
clean. If it is dam-
aged, consult author-
ized serviceman for 
repair and replace-
ment of the parts.

Follower hold-
er positions 
wrongly at 
the top of 
the magazine 
strip. 

Slide gently the 
follower holder to the 
bottom and release.

SYMPTOM 1

Contact Arm does not depress fully, tool 
does not operate.

SYMPTOM 3

Fan runs intermittently.

Summary of Contents for GT-3

Page 1: ...USER MANUAL Serious Connections TM GT 3 GT 3ST GAS TOOL...

Page 2: ...ecified by the manufacturer If the tool is weakened or damaged by Punching or engraving Modification not authorized by the manufacturer Guiding against templates made of hard material Dropping or push...

Page 3: ...s Exhaust gases in a confined space can be hazardous Do not use the tool outside in the rain or where excessive moisture in present Keep the tool from heat sources as the pressurized fuel cell could b...

Page 4: ...casualty become unconscious or breathing does not quickly return to normal summon urgent medical assistance If gas gets into the eyes they should be flushed out with copious amounts of water Skin cont...

Page 5: ...r a long time Recharge it in each 3 months can help to compensate the self discharged and keep the battery in a good condition The charging systems should store at a place out of reach of children Chi...

Page 6: ...Concrete 2 6mm Steel Plate to Hard Concrete 3 0mm step With changeable nose piece systems users are allowed to shoot for different purpose Please consult local agents for further details Only those f...

Page 7: ...remain alight 5 After charging unplug the charger from the power source If both lights are blinking in same pace remove the battery cartridge and plug again If this happens continuously the battery ca...

Page 8: ...r and create hazards to users and bystanders E Installing and removing fuel cell Caution Make sure the trigger is not held while inserting fuel cell Empty fasteners in the magazine before installing f...

Page 9: ...amming of pins could be evident if users cannot drive the fasteners properly try following steps in subsequent order Caution Place the tool on flat surface prior to releasing the magazine magazine may...

Page 10: ...ean the mesh with brush or air 3 Put the back cover on the machine and fasten with four screws NOTE Do not attempt to use water to clean the mesh The cover and mesh must be dry when operating the tool...

Page 11: ...by Authorized Serviceman TROUBLESHOOTING Normal Stage Of Operation Possible reasons Services Battery is discharged Charge Battery Cell Possible reasons Services Battery is loose or contacts are bent...

Page 12: ...not cycle fan runs Possible reasons Services Fuel Cell is empty Replace Fuel Cell Spark does not occur Contact authorized serviceman for repair SYMPTOM 4 Fail to drive fasteners Possible reasons Servi...

Page 13: ...t stable SYMPTOM 4 Unstable performance Possible reasons Services Built up dirt and debris inside cylinder Contact authorized serviceman for repair SYMPTOM 5 Diminishing power Possible reasons Service...

Page 14: ...Serious Connections TM ICCONS GAS TOOL GT 3 GT 3ST USER MANUAL 14 5 Parts List...

Page 15: ...S TRACK ST short 25 NB1100 SOCKET SCREW Blue 242 81 NB1ZA0 FOLLOWER 26 NB1290 METAL WASHER 82 NB1910 TRACK CAP 27 NB1170 LOCKNUT 83 NB1800 TRACK CONNECTOR 28 NB1380 METAL WASHER 84 NB1160 SOCKET SCREW...

Page 16: ...ong South Victoria 3175 Australia Passing on and duplication of this document exploitation and disclosure of its contents are forbidden unless expressly approved Violations render the offender liable...