ICCONS™ GAS TOOL GT-3 & GT-3ST USER MANUAL
SYMPTOM 3
Red and green LEDs on charger are
blinking simultaneously.
SYMPTOM 1
Fan does not run.
SYMPTOM 2
Fan does not run, or runs slower than
normal.
Possible
reasons
Services
Battery is hot. Remove battery from
charger and allow to
cool. Inspect battery
charger and cartridge.
Possible
reasons
Services
Battery
damaged
or cycle life
exhausted.
Replace Battery.
Possible
reasons
Services
Battery is not
charged.
Charge Battery
according to
Operating Manual.
Battery
Terminals
or Handle
battery
contacts are
oily, dirty, or
corroded.
Clean Battery Cell
terminals Clean
Handle Battery Cell
contacts as required.
There is
electrical
short
somewhere.
The tool must
be looked into
by Authorized
Serviceman.
TROUBLESHOOTING
Normal Stage Of Operation
Possible
reasons
Services
Battery is
discharged.
Charge Battery Cell.
Possible
reasons
Services
Battery is
loose or
contacts are
bent.
Snap battery back
into its locked
position. Bend
contacts back into
proper position.
TROUBLESHOOTING
Pre-Combustion/Combustion Stage of
Operation
Possible
reasons
Services
Lockout Bar is
stuck in lock-
out position.
Check if there is not
enough pins in the
channel, load extra
pins according to
Operating Manual.
The nose
piece is bent,
or the channel
is stuck with
dirt.
Inspect if the nose
piece and channel is
clean. If it is dam-
aged, consult author-
ized serviceman for
repair and replace-
ment of the parts.
Follower hold-
er positions
wrongly at
the top of
the magazine
strip.
Slide gently the
follower holder to the
bottom and release.
SYMPTOM 1
Contact Arm does not depress fully, tool
does not operate.
SYMPTOM 3