Note:
You
do
not
need
to
turn
off
the
power
to
the
server
to
install
hot-swap
power
supplies.
1
Power
supply
backplane
option
2
Cable-restraint
bracket
3
Power
supply
handle
(in
open
position)
4
Power
supply
5
Filler
panel
To
install
a
hot-swap
power
supply:
1.
Remove
the
filler
panel
from
the
empty
power
supply
bay
by
inserting
your
finger
into
the
depression
on
the
filler
panel
and
pulling
it
away
from
the
server.
Save
the
filler
panel
in
case
you
remove
the
power
supply
at
a
later
time.
Note:
During
normal
operation,
each
power-supply
bay
must
have
either
a
power
supply
or
filler
panel
installed
for
proper
cooling.
2.
Install
the
power
supply
in
the
bay:
a.
Place
the
handle
on
the
power
supply
in
the
open
position
(that
is,
perpendicular
to
the
power
supply)
and
slide
the
power
supply
into
the
chassis.
b.
Gently
close
the
handle
to
seat
the
power
supply
in
the
bay.
3.
Plug
the
power
cord
for
the
added
power
supply
into
the
power
cord
connector.
4.
Route
the
power
cord
through
the
cable-restraint
bracket.
5.
Plug
the
power
cord
into
a
properly
grounded
electrical
outlet.
6.
Verify
that
the
DC
Power
light
and
AC
Power
light
on
the
power
supply
are
lit,
indicating
that
the
power
supply
is
operating
correctly.
7.
If
you
have
other
options
to
install
or
remove,
do
so
now;
otherwise,
go
to“Installing
the
cover”
on
page
70.
Removing
a
hot-swap
power
supply
Attention:
If
you
have
not
installed
the
power
supply
backplane
option,
you
have
only
one
power
supply,
which
is
not
hot-swappable.
To
remove
the
single
power
supply,
or
the
only
remaining
hot-swap
power
supply,
go
to
“Removing
the
only
power
supply”
on
page
68.
Otherwise,
continue
with
the
following
procedure.
To
remove
a
hot-swap
power
supply:
Installing
options
67
Summary of Contents for xSeries 230 61Y
Page 1: ...Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 2: ......
Page 3: ...Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 20: ...12 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 38: ...30 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 48: ...40 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 126: ...118 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 132: ...124 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 167: ...Related service information 159...
Page 168: ...160 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 169: ...Related service information 161...
Page 170: ...162 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 171: ...Related service information 163...
Page 172: ...164 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 173: ...Related service information 165...
Page 174: ...166 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 184: ...176 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 185: ...Related service information 177...
Page 186: ...178 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 193: ......
Page 194: ...Part Number 19K6112 Printed in USA 1P P N 19K6112...