RAID battery backup status
Monitors the battery backup unit on the RAID controller.
From the WebGUI, click
STATUS
→
System
→
RAID Battery Backup
Status
.
From the command line, enter
show raid-battery-backup
.
Other sensors
Provides truth values for the intrusion switch, power supply modules,
batteries, and the hard disks.
v
A value of
true
indicates that the condition exists.
v
A value of
false
indicates that the conditions does not exist.
For the intrusion switch, the value indicates whether it has been tripped.
v
For each power supply, the value indicates the condition:
– Output Failure
– Present
v
For each hard disk in the array and the battery, the values indicates the
state:
– Fault
– Present
Note:
The hard disk drive modules are not hot-swappable. Hot
swapping the modules will cause your system to crash, and could
possibly damage your appliance.
v
From the WebGUI, click
STATUS
→
System
→
Other Sensors
.
v
From the command line, enter
show sensors-other
.