Table
21.
SNMP
trap
list
(continued)
Event
Event
description
Category
Reported
by
Selftest
display
bram
failure
The
diagnostic
buffer
that
is
used
to
report
test
results
is
not
large
enough
to
hold
the
data.
Critical
Diagnostics
Scb-fpga
camera
fifo
fail
The
memory
on
the
system
controller
board
has
failed
to
read
the
memory
that
is
used
to
transfer
data.
Critical
Diagnostics
Test
details
buffer
overflow
(len/testId)
The
diagnostic
buffer
that
reports
test
results
is
not
large
enough
to
hold
the
data.
Critical
Diagnostics
Test
record
semaphore
locked
(index/tx-status)
An
internal
firmware
error
has
occurred.
Critical
Diagnostics
Test
structure
corrupt
(testId)
An
internal
firmware
error
has
occurred.
Critical
Diagnostics
Insufficient
num
cart
for
test
(num)
There
are
not
enough
tape
cartridges
in
the
library
to
complete
the
system
test.
Warning
Diagnostics
Insufficient
num
drives
for
test
(num)
There
are
not
enough
tape
drives
in
the
library
to
complete
the
system
test.
Warning
Diagnostics
Insufficient
num
empty
slots
for
test
(num)
There
are
not
enough
empty
bins
in
the
library
to
complete
the
system
test.
Warning
Diagnostics
Hand-cal
offset
fail
The
library
failed
the
calibration
test
that
computes
offsets
for
the
robotic
hand.
Critical
Diagnostics
Hand-theta
cal
offset
fail
The
library
failed
the
calibration
test
that
computes
offsets
for
the
robotic
hand
in
rotation.
Critical
Diagnostics
Hand-trans
cal
offset
fail
The
library
failed
the
calibration
test
that
computes
offsets
for
the
robotic
hand
in
translation.
Critical
Diagnostics
XY
&
hand
cal
offset
fail
The
library
failed
the
calibration
test
that
computes
offsets
for
the
robotics
tray.
Critical
Diagnostics
XY
&
hand_theta
cal
offset
fail
The
library
failed
the
calibration
that
computes
offsets
for
the
robotics
tray
and
robotics
hand.
Critical
Diagnostics
XY
&
hand_trans
cal
offset
fail
The
library
failed
the
calibration
test
that
computes
offsets
for
the
robotics
tray
and
robotics
rotation.
Critical
Diagnostics
XY
&
Z
cal
offset
fail
The
library
failed
the
calibration
test
that
computes
offsets
for
the
robotics
tray
and
the
robotics
up
and
down
motion.
Critical
Diagnostics
XY-cal
offset
fail
The
library
failed
the
calibration
test
that
computes
offsets
for
the
robotics
tray.
Critical
Diagnostics
Z
&
hand
cal
offset
fail
The
library
failed
the
calibration
test
that
computes
offsets
for
the
robotics
tray
up
and
down
and
robotics
hand.
Critical
Diagnostics
Z
&
hand_theta
cal
offset
fail
The
library
failed
the
calibration
test
that
computes
offsets
for
the
robotics
tray
up
and
down
and
robotics
hand
rotation.
Critical
Diagnostics
Z
&
hand_trans
cal
offset
fail
The
library
failed
the
calibration
test
that
computes
offsets
for
the
robotics
tray
up
and
down
and
robotics
hand
translation.
Critical
Diagnostics
60
Universal
Tape
Library
User’s
Guide
Summary of Contents for Universal Tape Library
Page 1: ...Universal Tape Library User s Guide...
Page 2: ......
Page 3: ...Universal Tape Library User s Guide...
Page 10: ...viii Universal Tape Library User s Guide...
Page 46: ...36 Universal Tape Library User s Guide...
Page 52: ...42 Universal Tape Library User s Guide...
Page 60: ...50 Universal Tape Library User s Guide...
Page 68: ...58 Universal Tape Library User s Guide...
Page 84: ...74 Universal Tape Library User s Guide...
Page 90: ...80 Universal Tape Library User s Guide...
Page 94: ...84 Universal Tape Library User s Guide...
Page 95: ......
Page 96: ...Part Number 40M3720 Printed in USA 1P P N 40M3720...